Receivers
Compact design – easy to package
Stops the pig and does not allow push media past the pig — full product recovery
Reverses the disc lips prior to sending the pig back to launcher – ensures good sealing during return cycle
Easy to CIP or sterilize

Return sequences – Leaving receiver towards launcher
1. V2 purge valve (launching station) is opened
2. V5 push valve is opened forcing return media into line
3. Pig starts on return trip
4. Pig is detected in launching station
5. VR1 pig stop is extended
6. V2 purge valve is closed
7. V5 push valve is closed
System is cleaned and ready for CIP or production

Magnetic pig detectors
Installed in launcher/receivers or on piping system to detect pig
presence/passage – allow automated processes
Do not intrude in system – maintain cleanliness

NEXT PAGE